UVA Photodiode – SG01L-A5UVA
The SG01L-A5UVA is a Silicon Carbide (SiC)-based photodiode optimised for selective UVA detection across 315–400 nm, delivering accurate and interference-free ultraviolet monitoring. With a peak...
UVA Photodiode – SG01L-A5UVA
Large-Area UVA Photodiode for Precision Industrial, Medical, Environmental, Aerospace, and Scientific Monitoring Applications
The SG01L-A5UVA is a Silicon Carbide (SiC)-based photodiode optimised for selective UVA detection across 315–400 nm, delivering accurate and interference-free ultraviolet monitoring. With a peak responsivity of 0.12 A/W at 330 nm, it ensures precise UVA-only measurements without influence from UVB, UVC, visible, or IR radiation. Featuring a 0.8 mm² active area, the SG01L-A5UVA offers enhanced photon capture and strong photocurrent output, making it suitable for applications requiring higher sensitivity. Its ultra-low dark current of 0.2 fA and capacitance of 40 pF provide noise-free performance with rapid response times, even under low-intensity UVA conditions. Built to withstand harsh environments, the photodiode operates reliably across −55 °C to +170 °C, ensuring stability and durability. Applications include UVA curing, sterilisation monitoring, solar radiation research, aerospace UV sensing, workplace safety systems, and photonics R&D. The SG01L-A5UVA combines large-area sensitivity, durability, and UVA selectivity for mission-critical ultraviolet monitoring.
Understanding UVA Photodiode - SG01L-A5UVA
The SG01L-A5UVA is a large-area photodiode engineered for high-sensitivity UVA detection in the 315–400 nm range, with peak responsivity at 330 nm. Its 0.8 mm² active area allows for greater photon capture, producing stronger photocurrents and making it ideal for low-intensity or wide-beam UVA detection. The device delivers superior accuracy through SiC technology, ensuring complete suppression of unwanted visible and infrared light. With ultra-low dark current (0.2 fA) and 40 pF capacitance, it ensures high signal-to-noise ratios and fast response. Operating across −55 °C to +170 °C, the SG01L-A5UVA is highly reliable in industrial, aerospace, medical, and environmental applications.
Technical Specifications
| Feature | Specification |
| Typical Responsivity at Peak Wavelength | 0.12 A/W |
| Wavelength of Max. Responsivity | 330 nm |
| Responsivity Range (UVA Specific) | 315 … 400 nm |
| Visible Blindness | > 10¹⁰ |
| Active Area | 0.8 mm² |
| Dark Current (1 V reverse bias) | 0.2 fA |
| Capacitance | 40 pF |
| Short Circuit (10 mW/cm² at peak) | 3.8 µA |
| Temperature Coefficient | < 0.1 %/K |
| Operating Temperature | −55 … +170 °C |
| Storage Temperature | −55 … +170 °C |
| Soldering Temperature (3 s) | 260 °C |
| Maximum Reverse Voltage | 20 V |
Key Features and Advantages
Large Active Area for Enhanced Photon Capture
With its 0.8 mm² active area, the SG01L-A5UVA provides greater sensitivity and higher photocurrent outputs, making it ideal for wide-beam and low-intensity UVA applications.
Selective UVA Responsivity
It is designed for the 315–400 nm spectrum, peaking at 330 nm, ensuring precise UVA-only measurements while rejecting other wavelengths.
High Signal Clarity
The ultra-low dark current of 0.2 fA enables stable, noise-free readings, essential for critical UVA monitoring tasks.
Fast Response Capability
Capacitance of 40 pF allows the photodiode to respond quickly, supporting real-time UVA curing, sterilisation, and exposure monitoring systems.
Rugged Thermal Endurance
With a broad operating range from −55 °C to +170 °C, the device is designed for stability in aerospace, defence, and industrial environments.
Long-Term Stability and Reliability
SiC technology ensures resistance to UVA degradation, maintaining consistent performance over years of operation, minimising recalibration and downtime.
Flexible Integration
Its combination of large-area sensitivity and reliability makes it suitable for use in laboratory systems, medical devices, and industrial instrumentation.
The SG01L-A5UVA delivers high sensitivity, UVA precision, and rugged long-term reliability, ensuring dependable performance across industries.
Applications Across Industries
Industrial UVA Curing Systems
The SG01L-A5UVA supports curing systems in coatings, adhesives, and printing by ensuring accurate UVA intensity monitoring, improving consistency and quality control.
Medical and Healthcare Applications
It is ideal for sterilisation monitoring, phototherapy calibration, and UVA dosimetry in healthcare, ensuring precise radiation exposure levels.
Environmental and Solar Research
The device provides reliable measurements for solar radiation studies, atmospheric monitoring, and climate research where UVA accuracy is essential.
Laboratory and Photonics Research
Its selective UVA response makes it valuable in experiments requiring targeted UV measurement, including photonics, material science, and semiconductor studies.
Aerospace and Defence
The ruggedness and temperature stability of the SG01L-A5UVA make it well-suited for aerospace UV detection, arc monitoring, and defence-grade sensing systems.
Workplace and Industrial Safety
The photodiode can be integrated into UVA exposure monitoring systems to protect workers and ensure compliance with UV safety standards.
By combining large-area sensitivity, stability, and UVA-specific accuracy, the SG01L-A5UVA is trusted for critical industrial, medical, and research applications.
Why Choose United Spectrum Instruments?
-
Authorised distributor of SGLUX UVA photodiodes in India
-
Reliable local stock ensures faster delivery and shorter lead times
-
Competitive pricing tailored for industry, academia, and defence customers
-
Expert consultation for application-specific system integration
-
Nationwide after-sales support, training, and technical assistance
FAQs
What is the active area of the SG01L-A5UVA?
It has a large 0.8 mm² active area for stronger UVA sensitivity.
What is the responsivity peak?
It achieves 0.12 A/W at 330 nm.
What is its UVA detection range?
The device selectively detects UVA radiation from 315–400 nm.
Can it be used in extreme environments?
Yes, it operates reliably between −55 °C and +170 °C.
How does United Spectrum support customers in India?
By providing local inventory, expert consultation, fast delivery, and pan-India after-sales service.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What is the active area of the SG01L-A5UVA?
It has a large 0.8 mm² active area for stronger UVA sensitivity.
What is the responsivity peak?
It achieves 0.12 A/W at 330 nm.
What is its UVA detection range?
The device selectively detects UVA radiation from 315–400 nm.
Can it be used in extreme environments?
Yes, it operates reliably between −55 °C and +170 °C.
How does United Spectrum support customers in India?
By providing local inventory, expert consultation, fast delivery, and pan-India after-sales service.