UVA Photodetector – TOCON_A7UVA
The TOCON_A7UVA from SGLUX GmbH is a precision-calibrated UVA photodetector designed for accurate measurement of UVA radiation...
UVA Photodetector – TOCON_A7UVA
TOCON_A7UVA – High-Accuracy UVA Photodetector for Industrial Curing, Coating Inspection, and Scientific Measurement Applications
The TOCON_A7UVA from SGLUX GmbH is a precision-calibrated UVA photodetector designed for accurate measurement of UVA radiation in industrial, research, and photometric environments.
It incorporates a solar-blind Silicon Carbide (SiC) photodiode with an integrated low-noise transimpedance amplifier, delivering a clean and stable 0–5 V DC output directly proportional to incident UVA irradiance.
Operating across 320 nm – 400 nm, with a peak sensitivity near 350 nm, the sensor ensures reliable performance in UVA curing, polymerisation, and material testing.
Factory-calibrated and traceable to NIST / PTB standards, the TOCON_A7UVA provides outstanding accuracy, repeatability, and long-term stability.
Its compact, rugged housing and complete solar blindness make it the perfect tool for precision UVA process control, optical calibration, and photobiological research.
Understanding UVA Photodetector - TOCON_A7UVA
The TOCON_A7UVA measures UVA radiation between 320 nm and 400 nm, with its peak response at 350 nm, ensuring accurate detection of UVA energy while excluding visible or infrared light.
It features a SiC photodiode coupled with a transimpedance amplifier, providing a linear 0–5 V analog output, compatible with SENSOR MONITOR 5.0, VOLTCON, and SGCD4 systems.
Each sensor undergoes traceable calibration (NIST / PTB) to guarantee reproducible irradiance readings for UVA curing, inspection, and material analysis.
Compact, stable, and precise, it is ideal for applications requiring dependable, long-term UVA monitoring.
Technical Specifications
| Feature | Specification |
|---|---|
| Function | UVA photodetector for industrial and laboratory measurement |
| Detector Type | Solar-blind SiC photodiode with built-in transimpedance amplifier |
| Spectral Range | 320 – 400 nm |
| Peak Wavelength | 350 nm |
| Output Signal | 0 – 5 V DC (linear with irradiance) |
| Sensitivity | Optimised for UVA measurement |
| Accuracy | ± 5 % of reading |
| Response Time | < 1 s |
| Visible / IR Rejection | Complete solar blindness |
| Operating Voltage | 5 – 24 V DC |
| Operating Temperature | − 20 … + 85 °C |
| Housing Material | Anodised aluminium TOCON enclosure |
| Optical Window | UV-grade quartz |
| Connector | BNC / M8 / custom cable output |
| Calibration | Factory-calibrated, traceable to NIST / PTB |
| Compatibility | SENSOR MONITOR 5.0 / VOLTCON / SGCD4 systems |
| Applications | UVA curing, coating inspection, fluorescence excitation, polymer testing, photobiology, research and industrial monitoring |
Key Features and Advantages
Accurate UVA Sensitivity (320 – 400 nm)
The TOCON_A7UVA delivers precise UVA detection for processes requiring high-fidelity monitoring and control.
Solar-Blind SiC Technology
Its SiC photodiode eliminates visible and IR response, ensuring pure UVA sensitivity even in mixed-light environments.
Integrated Low-Noise Amplifier
The built-in amplifier provides a stable 0–5 V linear output, reducing noise and simplifying direct system integration.
Traceable Calibration for Confidence
Each sensor is NIST / PTB-calibrated, ensuring accurate, reproducible data across all operational environments.
Fast Response and Excellent Stability
Delivers sub-second response times with minimal drift, perfect for real-time curing and inspection applications.
Compact, Rugged Design
Built from anodised aluminium, the TOCON_A7UVA is robust and suited for demanding industrial conditions.
System Compatibility and Flexibility
Works seamlessly with SENSOR MONITOR 5.0, VOLTCON, and SGCD4, enabling plug-and-play deployment for both OEMs and researchers.
The TOCON_A7UVA stands as a dependable and traceable UVA sensor offering superior accuracy, repeatability, and durability—ideal for industrial curing, fluorescence inspection, and laboratory calibration tasks.
Applications Across Industries
UV Curing and Printing Applications
Ensures consistent UVA irradiance during adhesive bonding, varnish curing, and coating polymerisation.
Fluorescence and Surface Inspection
Measures UVA excitation for fluorescence detection, microscopy, and material identification.
Photobiological and Scientific Research
Used for photochemical, photobiology, and exposure experiments requiring high UVA measurement precision.
Radiometric and Optical Calibration
Acts as a reference detector for UVA light source calibration and validation of radiometric instruments.
Material Testing and Ageing Studies
Supports UVA exposure testing for polymers, coatings, and composite materials under controlled illumination.
Industrial Process Quality Control
Integrates into production lines to verify UVA lamp intensity and ensure uniform process results.
The TOCON_A7UVA provides traceable, high-stability UVA detection across diverse scientific and industrial sectors, guaranteeing accuracy, durability, and process reliability.
Why Choose United Spectrum Instruments?
-
Official distributor of SGLUX TOCON_A7UVA in India
-
Expertise in UVA and UV process-monitoring systems
-
Local calibration traceable to NIST / PTB standards
-
Integration and consultation support for OEMs and research institutions
-
Comprehensive pan-India technical and after-sales service
FAQs
What wavelengths does TOCON_A7UVA detect?
It measures 320–400 nm, peaking at 350 nm.
Does it detect visible or infrared light?
No – it’s solar-blind and rejects non-UVA radiation.
Is the device factory-calibrated?
Yes – it’s factory-calibrated and traceable to NIST / PTB standards.
Can it be used for curing and polymerisation systems?
Yes – ideal for UVA curing, coating, and UV process control.
How does United Spectrum support customers in India?
Through local calibration, integration support, and nationwide technical service for UV measurement systems.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What wavelengths does TOCON_A7UVA detect?
It measures 320–400 nm, peaking at 350 nm.
Does it detect visible or infrared light?
No – it’s solar-blind and rejects non-UVA radiation.
Is the device factory-calibrated?
Yes – it’s factory-calibrated and traceable to NIST / PTB standards.
Can it be used for curing and polymerisation systems?
Yes – ideal for UVA curing, coating, and UV process control.
How does United Spectrum support customers in India?
Through local calibration, integration support, and nationwide technical service for UV measurement systems.